Posted by Frank Molina, Stellavolta on
Nov 9th 2020
No, the solar panels do not have to be the same. You can mix and match different solar panels as long as it is within the microinverters specifications.
The SolarEdge SE3800H-US000BNU4 is compatible with Enphase optimizers P320, P320-ZEP, P340, P370, P400, P400-ZEP, P401, P405, P485, P505, Yes, with single phase inverters you would need a mininmum of
No, the SolarEdge SE-EV-KIT-25J40-1 Charge Connector 40 AMP is not compatible with older model inverters. It is only compatible with inverters that end in "NNV2". Currently, there are only two compati
To troubleshoot this issue, go to your OutBack Power MATE3s and check that the re-float setting matches the data points on your data sheet (float, bulk, absorption). They should match.
Yes, the latest OutBack Power FM60-150VDC and the FM80-150VDC are compatible with the OutBack Power MX60. Please refer to the OutBack Power User Forum discussion in the link below for more information
A MidNite Solar E-panel is an AC/DC Disconnect Box that simplifies inverter wiring and can include or have spaces for busbars, breakers, shunts, cables, etc. all in one convenient place.
The HUB10.3 allows OutBack Power's newer FXR inverter models to sub-phase stack. This method allows the inverters to stack in 3-phase, split phase, and single phase regardless of the model. Unlike old
Take the continuous power rating of your inverter, divide by the AC output voltage and multiply the result by 1.25.
For example, the OutBack Power VFXR3648A-01 inverter has a continuous power rating
The SMA SB5.0-1 SP-US-41 Sunny Boy will work with a 2070 Watt solar array. This inverters Minimum DC Voltage / Start Voltage is 100V in 208V system or 125V in a 240V system and a Maximum DC Voltage of