MidNite Solar MNDC-GFP50-300 Ground Fault Circuit Breaker 50 Amp 300VDC Din Rail Mount Ground Fault Protector. NRTL listed breaker assembly.
Use this assembly on PV circuits that operate up to 300VDC when required. NEC2008 requires DC-GFP's on all Solar installations. All MidNite circuit breakers are rated for 100% continuous duty. MidNite's breakers are rated to break the full rated load at the rated voltage repeatedly, with NO DAMAGE. Always use a properly sized breaker for disconnecting. All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.
Specifications
- 10,000 AIC
- Breaker Torque Value: 20 In-Lbs (2.3NM)
- Listed for US & Canada
- Weight: 2 lbs
FAQs
- Does the GFP breaker need to match my string voltage the same as a DC breaker?
Yes, the GFP breaker must match the string voltage the same as a DC breaker, however, the GFP breaker is not allowed as a disconnect and will not provide overcurrent protection. - Can I have two breakers on the same circuit, such as a DC breaker and a GFP breaker?
Yes, you can have two breakers on the same circuit. The DC breaker can act as a disconnect and will provide overcurrent protection, whereas the GFP breaker will provide ground-fault protection.